vCenter Server Appliance collector
The vCenter Server Appliance
using Health API
is a preconfigured Linux
virtual machine, which is optimized for running VMware vCenter Server® and the associated services on Linux.
This module collects health statistics from one or more vCenter Server Appliance
servers, depending on your
configuration.
Requirements
Metrics
All metrics have "vcsa." prefix.
Metric |
Scope |
Dimensions |
Units |
system_health |
global |
system |
status |
components_health |
global |
applmgmt, database_storage, mem, storage, swap |
status |
software_updates_health |
global |
software_packages |
status |
Health statuses
Overall System Health:
Numeric |
Text |
Description |
-1 |
unknown |
Module failed to decode status. |
0 |
green |
All components in the appliance are healthy. |
1 |
yellow |
One or more components in the appliance might become overloaded soon. |
2 |
orange |
One or more components in the appliance might be degraded. |
3 |
red |
One or more components in the appliance might be in an unusable status and the appliance might become unresponsive soon. |
4 |
gray |
No health data is available. |
Components Health:
Numeric |
Text |
Description |
-1 |
unknown |
Module failed to decode status. |
0 |
green |
The component is healthy. |
1 |
yellow |
The component is healthy, but may have some problems. |
2 |
orange |
The component is degraded, and may have serious problems. |
3 |
red |
The component is unavailable, or will stop functioning soon. |
4 |
gray |
No health data is available. |
Software Updates Health:
Numeric |
Text |
Description |
-1 |
unknown |
Module failed to decode status. |
0 |
green |
No updates available. |
2 |
orange |
Non-security patches might be available. |
3 |
red |
Security patches might be available. |
4 |
gray |
An error retrieving information on software updates. |
Configuration
Edit the go.d/vcsa.conf
configuration file using edit-config
from the
Netdata config directory, which is typically at /etc/netdata
.
cd /etc/netdata # Replace this path with your Netdata config directory
sudo ./edit-config go.d/vcsa.conf
Needs only url
, username
and password
. Here is an example for 2 servers:
jobs:
- name: vcsa1
url: https://203.0.113.0
username: admin@vsphere.local
password: somepassword
- name: vcsa2
url: https://203.0.113.10
username: admin@vsphere.local
password: somepassword
For all available options please see
module configuration file.
Troubleshooting
To troubleshoot issues with the vcsa
collector, run the go.d.plugin
with the debug option enabled. The output should
give you clues as to why the collector isn't working.
-
Navigate to the plugins.d
directory, usually at /usr/libexec/netdata/plugins.d/
. If that's not the case on
your system, open netdata.conf
and look for the plugins
setting under [directories]
.
cd /usr/libexec/netdata/plugins.d/
-
Switch to the netdata
user.
sudo -u netdata -s
-
Run the go.d.plugin
to debug the collector:
./go.d.plugin -d -m vcsa