Siemens S7 Input Plugin

This plugin reads metrics from Siemens PLCs via the S7 protocol.

Global configuration options

In addition to the plugin-specific configuration settings, plugins support additional global and plugin configuration settings. These settings are used to modify metrics, tags, and field or create aliases and configure ordering, etc. See the CONFIGURATION.md for more details.

Startup error behavior options

In addition to the plugin-specific and global configuration settings the plugin supports options for specifying the behavior when experiencing startup errors using the startup_error_behavior setting. Available values are:

  • error: Telegraf with stop and exit in case of startup errors. This is the default behavior.
  • ignore: Telegraf will ignore startup errors for this plugin and disables it but continues processing for all other plugins.
  • retry: Telegraf will try to startup the plugin in every gather or write cycle in case of startup errors. The plugin is disabled until the startup succeeds.

Configuration

# Plugin for retrieving data from Siemens PLCs via the S7 protocol (RFC1006)
[[inputs.s7comm]]
  ## Parameters to contact the PLC (mandatory)
  ## The server is in the <host>[:port] format where the port defaults to 102
  ## if not explicitly specified.
  server = "127.0.0.1:102"
  rack = 0
  slot = 0

  ## Connection or drive type of S7 protocol
  ## Available options are "PD" (programming  device), "OP" (operator panel) or "basic" (S7 basic communication).
  # connection_type = "PD"

  ## Max count of fields to be bundled in one batch-request. (PDU size)
  # pdu_size = 20

  ## Timeout for requests
  # timeout = "10s"

  ## Log detailed connection messages for tracing issues
  # log_level = "trace"

  ## Metric definition(s)
  [[inputs.s7comm.metric]]
    ## Name of the measurement
    # name = "s7comm"

    ## Field definitions
    ## name    - field name
    ## address - indirect address "<area>.<type><address>[.extra]"
    ##           area    - e.g. be "DB1" for data-block one
    ##           type    - supported types are (uppercase)
    ##                     X  -- bit, requires the bit-number as 'extra'
    ##                           parameter
    ##                     B  -- byte (8 bit)
    ##                     C  -- character (8 bit)
    ##                     W  -- word (16 bit)
    ##                     DW -- double word (32 bit)
    ##                     I  -- integer (16 bit)
    ##                     DI -- double integer (32 bit)
    ##                     R  -- IEEE 754 real floating point number (32 bit)
    ##                     DT -- date-time, always converted to unix timestamp
    ##                           with nano-second precision
    ##                     S  -- string, requires the maximum length of the
    ##                           string as 'extra' parameter
    ##           address - start address to read if not specified otherwise
    ##                     in the type field
    ##           extra   - extra parameter e.g. for the bit and string type
    fields = [
      { name="rpm",             address="DB1.R4"    },
      { name="status_ok",       address="DB1.X2.1"  },
      { name="last_error",      address="DB2.S1.32" },
      { name="last_error_time", address="DB2.DT2"   }
    ]

    ## Tags assigned to the metric
    # [inputs.s7comm.metric.tags]
    #   device = "compressor"
    #   location = "main building"

Example Output

s7comm,host=Hugin rpm=712i,status_ok=true,last_error="empty slot",last_error_time=1611319681000000000i 1611332164000000000

Metrics

The format of metrics produced by this plugin depends on the metric configuration(s).

Documentation

Index

Constants

This section is empty.

Variables

This section is empty.

Functions

This section is empty.

Types

type S7comm

type S7comm struct {
	Server          string             `toml:"server"`
	Rack            int                `toml:"rack"`
	Slot            int                `toml:"slot"`
	ConnectionType  string             `toml:"connection_type"`
	BatchMaxSize    int                `toml:"pdu_size"`
	Timeout         config.Duration    `toml:"timeout"`
	DebugConnection bool               `toml:"debug_connection" deprecated:"1.35.0;use 'log_level' 'trace' instead"`
	Configs         []metricDefinition `toml:"metric"`
	Log             telegraf.Logger    `toml:"-"`
	// contains filtered or unexported fields
}

func (*S7comm) Gather

func (s *S7comm) Gather(acc telegraf.Accumulator) error

func (*S7comm) Init

func (s *S7comm) Init() error

func (*S7comm) SampleConfig

func (*S7comm) SampleConfig() string

func (*S7comm) Start

func (s *S7comm) Start(telegraf.Accumulator) error

func (*S7comm) Stop

func (s *S7comm) Stop()

Jump to

Keyboard shortcuts

? : This menu
/ : Search site
f or F : Jump to
y or Y : Canonical URL