GroundWork Output Plugin
This plugin writes to a GroundWork Monitor instance. Plugin only supports
GW8+
Global configuration options
In addition to the plugin-specific configuration settings, plugins support
additional global and plugin configuration settings. These settings are used to
modify metrics, tags, and field or create aliases and configure ordering, etc.
See the CONFIGURATION.md for more details.
Secret-store support
This plugin supports secrets from secret-stores for the username
and
password
option.
See the secret-store documentation for more details on how
to use them.
Configuration
# Send telegraf metrics to GroundWork Monitor
[[outputs.groundwork]]
## URL of your groundwork instance.
url = "https://groundwork.example.com"
## Agent uuid for GroundWork API Server.
agent_id = ""
## Username and password to access GroundWork API.
username = ""
password = ""
## Default application type to use in GroundWork client
# default_app_type = "TELEGRAF"
## Default display name for the host with services(metrics).
# default_host = "telegraf"
## Default service state.
# default_service_state = "SERVICE_OK"
## The name of the tag that contains the hostname.
# resource_tag = "host"
## The name of the tag that contains the host group name.
# group_tag = "group"
- group - to define the name of the group you want to monitor,
can be changed with config.
- host - to define the name of the host you want to monitor,
can be changed with config.
- service - to define the name of the service you want to monitor.
- status - to define the status of the service. Supported statuses:
"SERVICE_OK", "SERVICE_WARNING", "SERVICE_UNSCHEDULED_CRITICAL",
"SERVICE_PENDING", "SERVICE_SCHEDULED_CRITICAL", "SERVICE_UNKNOWN".
- message - to provide any message you want,
it overrides message field value.
- unitType - to use in monitoring contexts (subset of The Unified Code for
Units of Measure standard). Supported types: "1", "%cpu", "KB", "GB", "MB".
- critical - to define the default critical threshold value,
it overrides value_cr field value.
- warning - to define the default warning threshold value,
it overrides value_wn field value.
- value_cr - to define critical threshold value,
it overrides critical tag value and value_cr field value.
- value_wn - to define warning threshold value,
it overrides warning tag value and value_wn field value.
NOTE
The current version of GroundWork Monitor does not support metrics whose values
are strings. Such metrics will be skipped and will not be added to the final
payload. You can find more context in this pull request: #10255.