This plugin reads data of one or more Uninterruptible Power Supplies
from an upsd daemon using its NUT network protocol.
Requirements
upsd should be installed and it's daemon should be running.
Global configuration options
In addition to the plugin-specific configuration settings, plugins support
additional global and plugin configuration settings. These settings are used to
modify metrics, tags, and field or create aliases and configure ordering, etc.
See the CONFIGURATION.md for more details.
Configuration
# Monitor UPSes connected via Network UPS Tools
[[inputs.upsd]]
## A running NUT server to connect to.
## IPv6 addresses must be enclosed in brackets (e.g. "[::1]")
# server = "127.0.0.1"
# port = 3493
# username = "user"
# password = "password"
## Force parsing numbers as floats
## It is highly recommended to enable this setting to parse numbers
## consistently as floats to avoid database conflicts where some numbers are
## parsed as integers and others as floats.
# force_float = false
Metrics
This implementation tries to maintain compatibility with the apcupsd metrics:
- upsd
- tags:
- fields:
- status_flags (status-bits)
- input_voltage
- load_percent
- battery_charge_percent
- time_left_ns
- output_voltage
- internal_temp
- battery_voltage
- input_frequency
- battery_date
- nominal_input_voltage
- nominal_battery_voltage
- nominal_power
- firmware
With the exception of:
- tags:
- status (string representing the set status_flags)
- fields:
Example Output
upsd,serial=AS1231515,ups_name=name1 load_percent=9.7,time_left_ns=9800000,output_voltage=230.4,internal_temp=32.4,battery_voltage=27.4,input_frequency=50.2,input_voltage=230.4,battery_charge_percent=100,status_flags=8i 1490035922000000000