Redfish Input Plugin

The redfish plugin gathers metrics and status information about CPU temperature, fanspeed, Powersupply, voltage, hostname and Location details (datacenter, placement, rack and room) of hardware servers for which DMTF's Redfish is enabled.

Telegraf minimum version: Telegraf 1.15.0

Global configuration options

In addition to the plugin-specific configuration settings, plugins support additional global and plugin configuration settings. These settings are used to modify metrics, tags, and field or create aliases and configure ordering, etc. See the CONFIGURATION.md for more details.

Configuration

# Read CPU, Fans, Powersupply and Voltage metrics of hardware server through redfish APIs
[[inputs.redfish]]
  ## Redfish API Base URL.
  address = "https://127.0.0.1:5000"

  ## Credentials for the Redfish API.
  username = "root"
  password = "password123456"

  ## System Id to collect data for in Redfish APIs.
  computer_system_id="System.Embedded.1"

  ## Tag sets allow you to include redfish OData link parent data
  ## For Example.
  ## Thermal data is an OData link with parent Chassis which has a link of Location.
  ## For more info see the Redfish Resource and Schema Guide at DMTFs website.
  ## Available sets are: "chassis.location" and "chassis"
  # include_tag_sets = ["chassis.location"]

  ## Amount of time allowed to complete the HTTP request
  # timeout = "5s"

  ## Optional TLS Config
  # tls_ca = "/etc/telegraf/ca.pem"
  # tls_cert = "/etc/telegraf/cert.pem"
  # tls_key = "/etc/telegraf/key.pem"
  ## Use TLS but skip chain & host verification
  # insecure_skip_verify = false

Metrics

  • redfish_thermal_temperatures

    • tags:
      • source
      • member_id
      • address
      • name
      • state
      • health
    • fields:
      • reading_celsius
      • upper_threshold_critical
      • upper_threshold_fatal
      • lower_threshold_critical
      • lower_threshold_fatal
  • redfish_thermal_fans

    • tags:
      • source
      • member_id
      • address
      • name
      • state
      • health
    • fields:
      • reading_rpm (or) reading_percent
      • upper_threshold_critical
      • upper_threshold_fatal
      • lower_threshold_critical
      • lower_threshold_fatal
  • redfish_power_powersupplies

    • tags:
      • source
      • member_id
      • address
      • name
      • state
      • health
    • fields:
      • last_power_output_watts
      • line_input_voltage
      • power_capacity_watts
      • power_input_watts
      • power_output_watts
  • redfish_power_voltages (available only if voltage data is found)

    • tags:
      • source
      • member_id
      • address
      • name
      • state
      • health
    • fields:
      • reading_volts
      • upper_threshold_critical
      • upper_threshold_fatal
      • lower_threshold_critical
      • lower_threshold_fatal

Tag Sets

  • chassis.location

    • tags:
      • datacenter (available only if location data is found)
      • rack (available only if location data is found)
      • room (available only if location data is found)
      • row (available only if location data is found)
  • chassis

    • tags:
      • chassis_chassistype
      • chassis_manufacturer
      • chassis_model
      • chassis_partnumber
      • chassis_powerstate
      • chassis_sku
      • chassis_serialnumber
      • chassis_state
      • chassis_health

Example Output

redfish_thermal_temperatures,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,health=OK,member_id=0,name=CPU1\ Temp,rack=WEB43,row=North,source=web483,state=Enabled reading_celsius=41,upper_threshold_critical=45,upper_threshold_fatal=48 1691270160000000000
redfish_thermal_temperatures,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,member_id=1,name=CPU2\ Temp,rack=WEB43,row=North,source=web483,state=Disabled upper_threshold_critical=45,upper_threshold_fatal=48 1691270160000000000
redfish_thermal_temperatures,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,health=OK,member_id=2,name=Chassis\ Intake\ Temp,rack=WEB43,row=North,source=web483,state=Enabled upper_threshold_critical=40,upper_threshold_fatal=50,lower_threshold_critical=5,lower_threshold_fatal=0,reading_celsius=25 1691270160000000000
redfish_thermal_fans,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,health=OK,member_id=0,name=BaseBoard\ System\ Fan,rack=WEB43,row=North,source=web483,state=Enabled lower_threshold_fatal=0i,reading_rpm=2100i 1691270160000000000
redfish_thermal_fans,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,health=OK,member_id=1,name=BaseBoard\ System\ Fan\ Backup,rack=WEB43,row=North,source=web483,state=Enabled lower_threshold_fatal=0i,reading_rpm=2050i 1691270160000000000
redfish_power_powersupplies,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,health=Warning,member_id=0,name=Power\ Supply\ Bay,rack=WEB43,row=North,source=web483,state=Enabled line_input_voltage=120,last_power_output_watts=325,power_capacity_watts=800 1691270160000000000
redfish_power_voltages,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,health=OK,member_id=0,name=VRM1\ Voltage,rack=WEB43,row=North,source=web483,state=Enabled upper_threshold_fatal=15,lower_threshold_critical=11,lower_threshold_fatal=10,reading_volts=12,upper_threshold_critical=13 1691270160000000000
redfish_power_voltages,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,health=OK,member_id=1,name=VRM2\ Voltage,rack=WEB43,row=North,source=web483,state=Enabled reading_volts=5,upper_threshold_critical=7,lower_threshold_critical=4.5 1691270160000000000
redfish_thermal_temperatures,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,health=OK,member_id=0,name=CPU1\ Temp,rack=WEB43,row=North,source=web483,state=Enabled upper_threshold_critical=45,upper_threshold_fatal=48,reading_celsius=41 1691270170000000000
redfish_thermal_temperatures,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,member_id=1,name=CPU2\ Temp,rack=WEB43,row=North,source=web483,state=Disabled upper_threshold_critical=45,upper_threshold_fatal=48 1691270170000000000
redfish_thermal_temperatures,address=127.0.0.1,chassis_chassistype=RackMount,chassis_health=OK,chassis_manufacturer=Contoso,chassis_model=3500RX,chassis_partnumber=224071-J23,chassis_powerstate=On,chassis_serialnumber=437XR1138R2,chassis_sku=8675309,chassis_state=Enabled,health=OK,member_id=2,name=Chassis\ Intake\ Temp,rack=WEB43,row=North,source=web483,state=Enabled lower_threshold_critical=5,lower_threshold_fatal=0,reading_celsius=25,upper_threshold_critical=40,upper_threshold_fatal=50 1691270170000000000

Documentation

Index

Constants

This section is empty.

Variables

This section is empty.

Functions

This section is empty.

Types

type Chassis

type Chassis struct {
	ChassisType  string
	Location     *Location
	Manufacturer string
	Model        string
	PartNumber   string
	Power        struct {
		Ref string `json:"@odata.id"`
	}
	PowerState   string
	SKU          string
	SerialNumber string
	Status       Status
	Thermal      struct {
		Ref string `json:"@odata.id"`
	}
}

type Location

type Location struct {
	PostalAddress struct {
		DataCenter string
		Room       string
	}
	Placement struct {
		Rack string
		Row  string
	}
}

type Power

type Power struct {
	PowerControl []struct {
		Name                string
		MemberID            string
		PowerAllocatedWatts *float64
		PowerAvailableWatts *float64
		PowerCapacityWatts  *float64
		PowerConsumedWatts  *float64
		PowerRequestedWatts *float64
		PowerMetrics        struct {
			AverageConsumedWatts *float64
			IntervalInMin        int
			MaxConsumedWatts     *float64
			MinConsumedWatts     *float64
		}
	}
	PowerSupplies []struct {
		Name                 string
		MemberID             string
		PowerInputWatts      *float64
		PowerCapacityWatts   *float64
		PowerOutputWatts     *float64
		LastPowerOutputWatts *float64
		Status               Status
		LineInputVoltage     *float64
	}
	Voltages []struct {
		Name                   string
		MemberID               string
		ReadingVolts           *float64
		UpperThresholdCritical *float64
		UpperThresholdFatal    *float64
		LowerThresholdCritical *float64
		LowerThresholdFatal    *float64
		Status                 Status
	}
}

type Redfish

type Redfish struct {
	Address          string          `toml:"address"`
	Username         string          `toml:"username"`
	Password         string          `toml:"password"`
	ComputerSystemID string          `toml:"computer_system_id"`
	IncludeTagSets   []string        `toml:"include_tag_sets"`
	Timeout          config.Duration `toml:"timeout"`

	tls.ClientConfig
	// contains filtered or unexported fields
}

func (*Redfish) Gather

func (r *Redfish) Gather(acc telegraf.Accumulator) error

func (*Redfish) Init

func (r *Redfish) Init() error

func (*Redfish) SampleConfig

func (*Redfish) SampleConfig() string

type Status

type Status struct {
	State  string
	Health string
}

type System

type System struct {
	Hostname string `json:"hostname"`
	Links    struct {
		Chassis []struct {
			Ref string `json:"@odata.id"`
		}
	}
}

type Thermal

type Thermal struct {
	Fans []struct {
		Name                   string
		MemberID               string
		Reading                *int64
		ReadingUnits           *string
		UpperThresholdCritical *int64
		UpperThresholdFatal    *int64
		LowerThresholdCritical *int64
		LowerThresholdFatal    *int64
		Status                 Status
	}
	Temperatures []struct {
		Name                   string
		MemberID               string
		ReadingCelsius         *float64
		UpperThresholdCritical *float64
		UpperThresholdFatal    *float64
		LowerThresholdCritical *float64
		LowerThresholdFatal    *float64
		Status                 Status
	}
}