README
¶
OVCLI: A HPE Synergy OneView Command Line Tool
OVCLI is a OneView CLI tool to manage Hewlett Packard Enterprise Synergy resources. It provides IT admins with a cross-platform HPE Synergy CLI utility that can directly run on Linux, Windows, and MAC operating systems without worrying about installing/troubleshooting any programming language library dependencies.
OVCLI tool communicates with Synergy OneView Restful API interface. It complements HPE OneView GUI interface to provide quicker Synergy access in many use cases.
Windows .EXE Download (Release 0.9, 12/12/2018)
For IT admins just want a simple small CLI tool, they can directly download the above .exe file. The image was compiled on windows2016 64-bit OS and tested also on windows2012R2 OS.
Docker Image
You can also use the tool in docker format. Docker hub link
User Tutorial Youtube Videos
Developer Source Code Access
OVCLI tool is written in Go bebind the scene. For developers, latest source code can be directly downloaded from the github repository by using go get
command and further compilied into binary executable file for the platform.
Release Notes
- Synergy 3.10 has been tested. Synergy 3.0 should work for most cases.
- For questions, please send email to hongjun.ma@hpe.com
Getting Started
- Verify executable file by running command
ovcli
either in the current directory or through system PATH environment setup. The succuss run should general the output like the sameple below.
$ ovcli
Release Version: 0.1
ovcli is a Synergy OneView CLI tool, please use "--help" option
to explore what are next available options
Usage:
ovcli [flags]
ovcli [command]
...
...
- Create a Synergy configuration text file including Synergy Mgmt IP address/hostname, login username and password in the current directory. It's a text file with the following three lines(please update with your corresponding login credentials and use "" if the string includes special characters)
ipaddress: 192.168.1.1
username: Administrator
password: "password"
- Populate OVCLI login configuration file and test the connection with HPE Synergy using the above file by running
ovcli login load -f "filname"
. (Behind the scene, the ovcli will copy the specified file to ovcli default config file "appliance-credential.yml"). You can verify configuration file contents and connection by usingovcli login show
andovcli login verify
command. A successful Synergy connection should come back with the Synergy API version. "500" below shows Synergy is running OneView version 3.10.
$ovcli login load -f syn2.yml
Successfully load "syn2.yml" to default configuration file appliance-credential.yml, use "ovcli login show" to verify
$ovcli login show
Login information in default configuration file: use "ovcli login verify" to verify credential
Synergy OneView IP Address: 10.16.43.100
Synergy OneView Username: Administrator
Synergy OneView Password: <trim>
$ovcli login verify
Connecting to Synergy OneView Appliance at "https://10.16.43.100" ...
Appliance Address Username Appliance Current Version
----------------- -------- -------------------------
https://10.16.43.100 Administrator 500
- With login credential verified, you can try different "ovcli show" commands like the following examples. "--help" or "-h" flag should give you help contexts for the commands.
Show Server Profiles
$ovcli show serverprofile Name Template Hardware Hardware Type DCA-ToR-Host17 Top - Frame1 - CN7515010J, bay 7 SY 480 Gen9 1 DCA-Tor-Host28 Middle - Frame 2 -CN75150484, bay 8 SY 480 Gen9 1 vsan node 1 vsan profile Middle - Frame 2 -CN75150484, bay 1 SY 480 Gen9 3 vsan node 2 vsan profile Middle - Frame 2 -CN75150484, bay 4 SY 480 Gen9 3 vsan node 3 vsan profile Middle - Frame 2 -CN75150484, bay 6 SY 480 Gen9 3
Show Server Profile details for one specific profile
$show serverprofile --name "vsan node 1"
------------------------------------------------------------------------------
Name: vsan node 1
Description:
ProfileTemplate: vsan profile
TemplateCompliance: Unknown
ServerHardware: Middle - Frame 2 -CN75150484, bay 1
ServerPower: Off
ServerHardwareType: SY 480 Gen9 3
Connections
ID Name Network VLAN MAC Port Interconnect Boot
1 vSAN Private 1 vSAN_Network 2000 F2:BA:A8:F0:01:B8 Mezz 3:1-d Top - Frame1 - CN7515010J, interconnect 3 NotBootable
2 vSAN Private 2 vSAN_Network 2000 F2:BA:A8:F0:01:B9 Mezz 3:2-d Middle - Frame 2 -CN75150484, interconnect 6 NotBootable
3 Vmotion Data 1 VLAN301-304 NetworkSet F2:BA:A8:F0:01:BA Mezz 3:1-c Top - Frame1 - CN7515010J, interconnect 3 NotBootable
4 Vmotion dAta 2 VLAN301-304 NetworkSet F2:BA:A8:F0:01:BB Mezz 3:2-c Middle - Frame 2 -CN75150484, interconnect 6 NotBootable
5 Mgmt 1 TE-Testing-300 300 F2:BA:A8:F0:01:BC Mezz 3:1-b Top - Frame1 - CN7515010J, interconnect 3 NotBootable
6 Mgmt 2 TE-Testing-300 300 F2:BA:A8:F0:01:BD Mezz 3:2-b Middle - Frame 2 -CN75150484, interconnect 6 NotBootable
Show MAC address table for a vlan or a MAC
ovcli show mac --vlan 140
Name Module Port VLAN
EC:B1:D7:7E:35:4D Frame 01 Bottom, interconnect 3 Q5:1 140
00:2A:6A:AD:16:3C Frame 01 Bottom, interconnect 3 Q5:1 140
00:00:0C:07:AC:8C Frame 01 Bottom, interconnect 3 Q5:1 140
EC:B1:D7:7E:35:49 Frame 01 Bottom, interconnect 3 Q5:1 140
EC:B1:D7:7E:35:48 Frame 01 Bottom, interconnect 3 Q5:1 140
FE:E1:D0:10:00:48 Frame 01 Bottom, interconnect 3 downlink 3:3-4 140
3C:D9:2B:F7:71:60 Frame 01 Bottom, interconnect 3 Q5:1 140
00:2A:6A:AD:16:7C Frame 01 Bottom, interconnect 3 Q5:1 140
00:50:56:6A:72:C4 Frame 01 Bottom, interconnect 3 downlink 30:3-4 140
7A:2A:1D:30:00:06 Frame 01 Bottom, interconnect 3 Q5:1 140
5C:B9:01:78:16:38 Frame 01 Bottom, interconnect 3 Q5:1 140
00:2A:6A:AD:16:F6 Frame 01 Bottom, interconnect 3 Q5:1 140
Show logical uplink details for all LIs
$ ovcli show li --name all
------------------------------------------------------------------------------
SSA-DCA-3Frame-DCA-Solcenter-LIG-Copy
UplinkSet: DCA-ToR
Networks:
Network Name VlanID Type
------------ ------ ----
DCA-ACI-VMM-Pool__1041 1041 Tagged
DCA-ACI-VMM-Pool__1042 1042 Tagged
DCA-ACI-VMM-Pool__1043 1043 Tagged
DCA-ACI-VMM-Pool__1044 1044 Tagged
DCA-ACI-VMM-Pool__1045 1045 Tagged
DCA-ACI-VMM-Pool__1046 1046 Tagged
DCA-ACI-VMM-Pool__1047 1047 Tagged
DCA-ACI-VMM-Pool__1048 1048 Tagged
DCA-ACI-VMM-Pool__1049 1049 Tagged
DCA-ACI-VMM-Pool__1050 1050 Tagged
DCA-ACI-VMM-Pool__1051 1051 Tagged
DCA-ACI-VMM-Pool__1052 1052 Tagged
DCA-ACI-VMM-Pool__1053 1053 Tagged
DCA-ACI-VMM-Pool__1054 1054 Tagged
DCA-ACI-VMM-Pool__1055 1055 Tagged
DCA-ACI-VMM-Pool__1056 1056 Tagged
DCA-ACI-VMM-Pool__1057 1057 Tagged
DCA-ACI-VMM-Pool__1058 1058 Tagged
DCA-ACI-VMM-Pool__1059 1059 Tagged
DCA-ACI-VMM-Pool__1060 1060 Tagged
DCA-ACI-VMM-Pool__1061 1061 Tagged
DCA-ACI-VMM-Pool__1062 1062 Tagged
DCA-ACI-VMM-Pool__1063 1063 Tagged
DCA-ACI-VMM-Pool__1064 1064 Tagged
DCA-ACI-VMM-Pool__1065 1065 Tagged
DCA-ACI-VMM-Pool__1066 1066 Tagged
DCA-ACI-VMM-Pool__1067 1067 Tagged
DCA-ACI-VMM-Pool__1068 1068 Tagged
DCA-ACI-VMM-Pool__1069 1069 Tagged
DCA-ACI-VMM-Pool__1070 1070 Tagged
DCA-ACI-VMM-Pool__1071 1071 Tagged
DCA-ACI-VMM-Pool__1072 1072 Tagged
DCA-ACI-VMM-Pool__1073 1073 Tagged
DCA-ACI-VMM-Pool__1074 1074 Tagged
DCA-ACI-VMM-Pool__1075 1075 Tagged
DCA-ACI-VMM-Pool__1076 1076 Tagged
DCA-ACI-VMM-Pool__1077 1077 Tagged
DCA-ACI-VMM-Pool__1078 1078 Tagged
DCA-ACI-VMM-Pool__1079 1079 Tagged
DCA-ACI-VMM-Pool__1080 1080 Tagged
DCA-ACI-VMM-Pool__1081 1081 Tagged
DCA-ACI-VMM-Pool__1082 1082 Tagged
DCA-ACI-VMM-Pool__1083 1083 Tagged
DCA-ACI-VMM-Pool__1084 1084 Tagged
DCA-ACI-VMM-Pool__1085 1085 Tagged
DCA-ACI-VMM-Pool__1086 1086 Tagged
DCA-ACI-VMM-Pool__1087 1087 Tagged
DCA-ACI-VMM-Pool__1088 1088 Tagged
DCA-ACI-VMM-Pool__1089 1089 Tagged
DCA-ACI-VMM-Pool__1090 1090 Tagged
DCA-Host-mgmt2 150 Tagged
DCA-VLAN-Pri 500 Tagged
DCA-VLAN-Sec 510 Tagged
UplinkPort:
Enclosure IOBay Port
--------- ----- ----
Middle - Frame 2 -CN75150484 6 Q3:1
Middle - Frame 2 -CN75150484 6 Q4:1
Top - Frame1 - CN7515010J 3 Q3:1
Top - Frame1 - CN7515010J 3 Q4:1
UplinkSet: Tech-Enablement-Testing
Networks:
Network Name VlanID Type
------------ ------ ----
TE-Testing-300 300 Tagged
TE-Testing-301 301 Tagged
TE-Testing-302 302 Tagged
TE-Testing-303 303 Tagged
TE-Testing-304 304 Tagged
vSAN_Network 2000 Tagged
UplinkPort:
Enclosure IOBay Port
--------- ----- ----
Middle - Frame 2 -CN75150484 6 Q5
Top - Frame1 - CN7515010J 3 Q5
Index Enclosure IOBay ModelName PartNumber
1 Top - Frame1 - CN7515010J 3 Virtual Connect SE 40Gb F8 Module for Synergy 794502-B23
1 Top - Frame1 - CN7515010J 6 Synergy 20Gb Interconnect Link Module 779218-B21
2 Middle - Frame 2 -CN75150484 3 Synergy 20Gb Interconnect Link Module 779218-B21
2 Middle - Frame 2 -CN75150484 6 Virtual Connect SE 40Gb F8 Module for Synergy 794502-B23
3 CN7515048Q 3 Synergy 20Gb Interconnect Link Module 779218-B21
3 CN7515048Q 6 Synergy 20Gb Interconnect Link Module 779218-B21
Documentation
¶