heatpump

command module
v0.0.0-...-4ac913f Latest Latest
Warning

This package is not in the latest version of its module.

Go to latest
Published: Jul 9, 2024 License: BSD-2-Clause Imports: 6 Imported by: 0

README

Viessman Vitocal 100A, Rinnai Shimanto, Thermocold MEX Vsx, Maxa i-32V5 - Heatpump Telemetry

Purpose

Heatpump telemetry for makes/models: Viessmann Vitocal 100A, Rinnai Shimanto, Thermocold MEX Vsx, Maxa i-32V5 series is decoded to json and posted to a mosquitto topic

Description

This service reads the MODBUS communications between a Viessmann Remote Touch Controller (master) and a Vitocal 100A heatpump (slave) and posts heatpump data in json format to an MQTT topic. A Remote Touch Controller (RTC) is essential because this service only reads MODBUS data, it does not query the heatpump directly. The Remote Touch Controller is the MODBUS master that initiates the communications with a Vitocal 100A heatpump and queries its telemetry. It could be possible to reproduce the queries sent by the RTC, however this service was designed to be read only in order to avoid the risk of sending unwanted configuration changes to the heatpump.

Note

Viessmann, Rinnai, Thermocold MODBUS data packets are undocumented (The Manufacturers do not provide documentation), they have been decoded by observing the heatpump behaviour and patterns and thus in some cases they might be inaccurate or incorrect.

Decoding

Four query/response records have been decoded, each are identified by their length

MODBUS Read Registers Records

A Vitocal 100A response record looks as follows:

+--------------------------------+
| AA FF SZ VVVV1 VVVV2 VVVx CKSM |
+--------------------------------+
AA = Modbus Address, 1 Byte (default = 1)
FF = Modbus Function, 1 Byte (read registers = 3)
SZ = Data registers size in bytes (1 register = 2 bytes), 1 Byte
VVV1 = Register 1
VVV2 = Register 2
VVVx = Register x
CKSM = Checksum (inverted bytes)

Four response types have been identified: STATES, MACHINE, TEMPERATURES, ERRORS. The record type is indentified by its size which is fixed for each type

STATES       = 27 bytes
MACHINE      = 11 bytes
TEMPERATURES = 100 bytes
ERRORS       = 15 bytes

The data payload size for each type is its size less 5 bytes (1 byte for the address, 1 byte for function, 1 byte for payload size, 2 bytes for checksum), thus the validity of a response record is verified by checking that the value of the third byte (payload size) is equal the total record size less five.

See RECORDS.md for MODBUS telemetry decoding

JSON telemetry data

This service reads the modbus data stream from the heat pump and encodes it into data stream in json format that is publised to a mosquitto topic. When the heatpump is in standby, records sent to mosquitto are throttled down to one every X seconds (where X is a configurable value) to reduce network traffic.

{
    "timestamp":"2022-11-14T11:45:19.454544965+01:00",
    "control_mode": 2,
    "status":0,
    "mode":1,
    "compressor_required":false,
    "compressor_status":0,
    "compressor_hz":0,
    "pump_status":0,
    "pump_speed":0,
    "fan_speed":0,
    "temperatures":{
        "water_in":"18.7",
        "water_out":"17.9",
        "external":"15.6",
        "compressor_in":"17.0"
        "compressor_out":"50.5"
    },
    "pressure_high":1189,
    "pressure_low":1201,
    "hours":17,
    "errors":{
        "error_1":0,
        "error_2":0,
        "error_3":0,
        "error_4":0,
        "error_5":0
    }
Notes