templates/

directory
v0.0.0-...-3371691 Latest Latest
Warning

This package is not in the latest version of its module.

Go to latest
Published: Nov 11, 2023 License: MIT

README

Templates folder documentation

Folders

  • defintion: hold all device templates definitons in yaml files
    • charger: all charger templates
    • meter: all meter templates
    • vehicle: all vehicle templates
  • docs: content is generated via go generate ./... using the above templates for the evcc documentation page to be used

Template Documentation

The following describes each possible element in a yaml file

template

template expects a unique template name for the current device class (charger, meter, vehicle are device classes)

products

products expects a list of products that work with this template.

Each product contains:

  • brand: an optional brand description of the product
  • description: an optional description e.g. of the product model. Expects generic, de, en: an optional description of the product

Either brand, or description need to be set.

group

group is used to group switchable sockets and generic device support (e.g. SunSpec) templates.

guidedsetup (Obsolete)

guidedsetup is enabled when the device has linked templates or >1 usage. It is used with devices that provide multiple meter usages, or meter devices that are typically installed with specific other devices. Mostly used for meter devices that provided multiple usage data with the same user input. These devices are then sorted at the bottom of the product list.

linked

Allows to define a list of meter devices that are typically installed with this device. Enables guidedsetup mode.

template

template expects the linked device template value

usage

usage expects the meter usage type this device will be used for

Possible values:

  • grid: for grid meters
  • pv: for pv inverter/meter
  • battery: for battery inverter/meter
multiple

multiple:true to define that multiple devices of this template can be added

excludetemplate

excludetemplate defines a linked device template value. If defined and a device of the linked template is added, then this linked template won't be considered in the flow

Example Use Case: With SMA Home Manager, there can be a SMA Energy Meter used for getting the PV generation or multiple SMA PV inverters. But never both together. So if the used added an SMA Energy Meter, then the flow shoudn't ask for SMA PV inverters.

capabilities

capabilities provides an option to define special capabilities of the device as a list of strings

Possible Values:

  • iso151182: If the charger supports communicating via ISO15118-2
  • rfid: If the charger supports RFID
  • 1p3p: If the charger supports 1P/3P-phase switching
  • smahems: If the device can be used as an SMA HEMS device, only used for the SMA Home Manager 2.0 right now

requirements

requirements provides an option to define various requirements / dependencies that need to be setup

evcc

evcc is a list of evcc specific system requirements

Possible Values:

  • sponsorship: If the device requires a sponsorship token
  • eebus: If the device is accessed via the eebus protocol and thus requires the corresponding setup
  • mqtt: If the device a MQTT setup
description

description expects language specific texts via de, en to provide specific things the user has to do, e.g. minimum firmware versions or specific hardware setup requirements. The content can be multiline and Markdown

uri

uri is a link providing more help on the requirements

loglevel

loglevel defindes the name that can be used in the levels configuration for adjusting the log level of individual devices/components/...

params

params describes the set of parameters the user needs to provide a value for.

preset

preset reference value of a predefined params set defined in parambaselist.yaml, so these params don't need to be redefined in each template. The example and default values for each predefined value can be overwritten.

name

name expects a name for the parameter, which will be used in the render section to reference the param and provide the user entered value.

Note: There a few default name values with specific internal meaning and consequences!

Predefined name values:

  • usage: specifies a list of meter classes, the device can be used for. Possible values are grid, pv, battery, and charger
  • modbus: specifies that this device is accessed via modbus. It requires the choice property to have a list of possible interface values the device provides. These values can be rs485 and tcpip. The command will use either to ask the appropriate questions and settings. The render section needs to include the string {{include "modbus" .}} in all places where the configuration needs modbus settings.
Usage Options
  • allineone: Defines if the different usages are all available in a single device. Enables guidedsetup mode.
Modbus Options
  • id: Device specific default for modbus ID
  • port: Device specific default for modbus TCPIP port
  • baudrate: Device specific default for modbus RS485 baudrate
  • comset: Device specific default for modbus RS485 comset
description

description allows to define user friendly and language specific names via de, en, generic

dependencies

dependencies allows to define a list of checks, when this param should be presented to the user, if it should be only in special cases

name

name referenced the param name value

check

check defines which kind of check should be performed

Possible values:

  • empty: if the value of the referenced param name should be empty
  • notempty: if the value of the referenced param name should be NOT empty
  • equal: if the value of the referenced param name should match the value of the value property
value

value property is used in the equal check

required

required: true defines if the user has to provide a value. Default is false

mask

mask: true defines if the user input should be masked, e.g. for passwords. Defaut is false

default

default defines a default value to be used. For these cases the user can then simply press enter in the CLI.

example

example provides an example value, so the user can get an idea of what is expected and what to look out for

type

type allows to define the value type to let the CLI verify the user provided content

Possible values:

  • string: for string values (default)
  • bool: for true and false values. If help is provided, than that help text is presented as the question
  • number: for int values
  • float: for float values
  • stringlist: for a list of strings, e.g.used for defining a list of identifiers for vehicles
  • chargemodes: for a selection of charge modes (including None which results in the param not being set)
advanced

advanced allows to specify if the param should only be asked if the cli is run with --advanced. Mostly used for non required params that are meant for users with advanced needs and knowledge.

help

help expects language specific help texts via generic (language independent), de, en

render

render contains the internal device configuration. All param name values can be used as a template variable, e.g. {{ .host }} for a param named host. The content is a go template, so all of go template feature can be used, e.g. {{- if ... }} statements, etc.

Directories

Path Synopsis

Jump to

Keyboard shortcuts

? : This menu
/ : Search site
f or F : Jump to
y or Y : Canonical URL