config

package
v0.2.0 Latest Latest
Warning

This package is not in the latest version of its module.

Go to latest
Published: Apr 19, 2016 License: Apache-1.1 Imports: 0 Imported by: 0

Documentation

Overview

Package config declares application and session settings for QuickFIX/Go

BeginString

Version of FIX this session should use. Valid values:

FIXT.1.1
FIX.4.4
FIX.4.3
FIX.4.2
FIX.4.1
FIX.4.0

SenderCompID

Your ID as associated with this FIX session. Value is case-sensitive alpha-numeric string.

TargetCompID

Counter parties ID as associated with this FIX session. Value is case-sensitive alpha-numeric string.

SessionQualifier

Additional qualifier to disambiguate otherwise identical sessions. Value is case-sensitive alpha-numeric string.

DefaultApplVerID

Required only for FIXT 1.1 (and newer). Ignored for earlier transport versions. Specifies the default application version ID for the session. This can either be the ApplVerID enum (see the ApplVerID field) or the BeginString for the default version. Valid Values:

FIX.5.0SP2
FIX.5.0SP1
FIX.5.0
FIX.4.4
FIX.4.3
FIX.4.2
FIX.4.1
FIX.4.0
9
8
7
6
5
4
3
2

ResetOnLogon

Determines if sequence numbers should be reset when recieving a logon request. Acceptors only. Valid Values:

Y
N

Defaults to N.

Validation

The following settings are specific to message validation.

DataDictionary

XML definition file for validating incoming FIX messages. If no DataDictionary is supplied, only basic message validation will be done.

This setting should only be used with FIX transport versions older than FIXT.1.1. See TransportDataDictionary and AppDataDictionary for FIXT.1.1 settings. Value must be a valid XML data dictionary file. QuickFIX/Go comes with the following defaults in the spec directory

FIX44.xml
FIX43.xml
FIX42.xml
FIX41.xml
FIX40.xml

TransportDataDictionary

XML definition file for validating admin (transport) messages. This setting is only valid for FIXT.1.1 (or newer) sessions. See DataDictionary for older transport versions (FIX.4.0 - FIX.4.4) for additional information. Value must be a valid XML data dictionary file, QuickFIX/Go comes with the following defaults in the spec directory

FIXT1.1.xml

AppDataDictionary

XML definition file for validating application messages. This setting is only valid for FIXT.1.1 (or newer) sessions. See DataDictionary for older transport versions (FIX.4.0 - FIX.4.4) for additional information.

This setting supports the possibility of a custom application data dictionary for each session. This setting would only be used with FIXT 1.1 and new transport protocols. This setting can be used as a prefix to specify multiple application dictionaries for the FIXT transport. For example:

DefaultApplVerID=FIX.4.2
# For default application version ID
AppDataDictionary=FIX42.xml
# For nondefault application version ID
# Use BeginString suffix for app version
AppDataDictionary.FIX.4.4=FIX44.xml

Value must be a valid XML data dictionary file. QuickFIX/Go comes with the following defaults in the spec directory

FIX50SP2.xml
FIX50SP1.xml
FIX50.xml
FIX44.xml
FIX43.xml
FIX42.xml
FIX41.xml
FIX40.xml

HeartBtInt

Heartbeat interval in seconds. Only used for initiators. Value must be positive integer.

SocketConnectPort

Socket port for connecting to a session. Only used for initiators. Must be positive integer

SocketConnectHost

Host to connect to. Only used for initiators. Value must be valid IP address in the format of x.x.x.x or a domain name

SocketAcceptPort

Socket port for listening to incoming connections, Only used with for acceptors. Value must be positive integer, valid open socket port.

FileLogPath

Directory to store logs. Value must be valid directory for storing files, application must have write access.

FileStorePath

Directory to store sequence number and message files. Only used with FileStoreFactory.

SQLDriver

The name of the database driver to use (see https://github.com/golang/go/wiki/SQLDrivers for the list of available drivers). Only used with SqlStoreFactory.

SQLDataSourceName

The driver-specific data source name of the database to use. Only used with SqlStoreFactory.

Index

Constants

View Source
const (
	BeginString             string = "BeginString"
	SenderCompID            string = "SenderCompID"
	TargetCompID            string = "TargetCompID"
	SessionQualifier        string = "SessionQualifier"
	SocketAcceptPort        string = "SocketAcceptPort"
	SocketConnectHost       string = "SocketConnectHost"
	SocketConnectPort       string = "SocketConnectPort"
	DefaultApplVerID        string = "DefaultApplVerID"
	DataDictionary          string = "DataDictionary"
	TransportDataDictionary string = "TransportDataDictionary"
	AppDataDictionary       string = "AppDataDictionary"
	ResetOnLogon            string = "ResetOnLogon"
	HeartBtInt              string = "HeartBtInt"
	FileLogPath             string = "FileLogPath"
	FileStorePath           string = "FileStorePath"
	SQLDriver               string = "SQLDriver"
	SQLDataSourceName       string = "SQLDataSourceName"
)

Variables

This section is empty.

Functions

This section is empty.

Types

This section is empty.

Jump to

Keyboard shortcuts

? : This menu
/ : Search site
f or F : Jump to
y or Y : Canonical URL