Modbus exporter
Prometheus exporter which retrieves stats from a modbus tcp system and exports
them via HTTP for Prometheus consumption.
Reproduce diagram
Go to: https://bramp.github.io/js-sequence-diagrams/
Note right of Prometheus: prometheus.yml \n --- \n target: Modbus-TCP-10.0.0.5 \n sub_target: Modbus-Unit-10 \n module: VendorXY
Prometheus->Exporter: http://xxx.de/modbus?target=10.0.0.5&sub_target=10&module=vendorxy
Note right of Exporter: modbus.yml \n --- \n module: VendorXY \n - temperature_a: 400001 \n - temperature_b: 400002
Exporter->Modbus_TCP_10.0.0.5: tcp://10.0.0.5?unit=10®ister=400001
Modbus_TCP_10.0.0.5->Modbus_RTU_10: rtu://_?register=400001
Modbus_RTU_10-->Modbus_TCP_10.0.0.5: value=20
Modbus_TCP_10.0.0.5-->Exporter: value=20
Exporter->Modbus_TCP_10.0.0.5: tcp://10.0.0.5?unit=10®ister=400002
Modbus_TCP_10.0.0.5->Modbus_RTU_10: rtu://_?register=400002
Modbus_RTU_10-->Modbus_TCP_10.0.0.5: value=19
Modbus_TCP_10.0.0.5-->Exporter: value=19
Exporter-->Prometheus:temperature_a{module="VendorXY",sub_target="10"} 20 \ntemperature_b{module="VendorXY",sub_target="10"} 19
Building
make build
Getting Started
The modbus exporter needs to be passed target (including port), module and sub_module as parameters
by Prometheus, this can be done with relabelling (see
prometheus.yml).
Once Prometheus is properly configured, run the exporter via:
./modbus_exporter [flags]
Supported flags:
usage: modbus_exporter [<flags>]
Flags:
-h, --[no-]help Show context-sensitive help (also try
--help-long and --help-man).
--config.file="modbus.yml"
Sets the configuration file.
--[no-]web.systemd-socket Use systemd socket activation listeners instead
of port listeners (Linux only).
--web.listen-address=:9602 ...
Addresses on which to expose metrics and web
interface. Repeatable for multiple addresses.
--web.config.file="" [EXPERIMENTAL] Path to configuration file that
can enable TLS or authentication.
--log.level=info Only log messages with the given severity or
above. One of: [debug, info, warn, error]
--log.format=logfmt Output format of log messages. One of: [logfmt,
json]
--[no-]version Show application version.
Visit http://localhost:9602/modbus?target=1.2.3.4:502&module=fake&sub_target=1 where 1.2.3.4:502 is the IP and port number of the modbus IP device to get metrics from,
while module and sub_target parameters specify which module and subtarget to use from the config file.
If your device doesn't use sub-targets you can usually just set it to 1.
Visit http://localhost:9602/metrics to get the metrics of the exporter itself.
Configuration File
Check out modbus.yml
for more details on the configuration file
format.
TODO
Misc info
ModBus RTU
Support for serial ModBus (RTU) was dropped in git commit d06573828793094fd2bdf3e7c5d072e7a4fd381b.
Please send a PR if you need it again.
For now, we suggest using a ModBus PLC/bridge/master to bridge from RTU into TCP.