Modbus simulator
Modbus simulator will let you start a modbus slave with pregenerated dataset's that will be read from json files provided by the caller.
Run / build
In an environment where Go is installed.
To run the code directly
go run main.go --help
To build an executable for Linux amd64 architecture.
env GOOS=linux GOARCH=amd64 go build
Precombiled executable binary for Linux amd64
modbusgenerator
JSON config file
The config for a specific register are specified in a JSON file. Each type of register coil|discrete|input|handler must be specified in it's own separate config file, so for example a coil register must be specified in it's own file, a discrete register in it's own file, and so on.
An example of a JSON config file for a holding register.
[{
"type": "float32LittleWordBigEndian",
"number": 3.1415,
"regAddr": 101
}, {
"type": "float32BigWordBigEndian",
"number": 3.1415926,
"regAddr": 103
}, {
"type": "float32BigWordBigEndian",
"number": 3.101010,
"regAddr": 105
}]
The general structure are to specify one or more elements where each element describes a single address in the specific register.
Explanation of the elements:
-
type: There are in general 6 types to choose from:
- float32LittleWordBigEndian Value of 2 x uint16, where the two uints have swapp'ed order, and the byte order within each uint is in normal order.
- float32BigWordBigEndian Value of 2 x uint16, where the two uints are in normal order, and the byte order within each uint is in normal order.
- float32LittleWordLittleEndian Value of 2 x uint16, where the two uints have swapp'ed order, and the byte order within each uint is in swap'ed order.
- float32BigWordLittleEndian Value of 2 x uint16, where the two uints are in normal order, and the byte order within each uint is in swap'ed order.
- wordInt16BigEndian Value of a single uint16, where the byte order is in normal order. This is generally used for coil and discrete registers.
- wordInt16LittleEndian Value of a single uint16, where the byte order is in swap'ed order. Generally not used.
Numbers for :
- input and holding registers are float values.
- coil and discrete values are 0 or 1.
regAddr are integer values representing the address number.
Flags provided by the modbus simulator
Description of flags provided by modbus generator.
-jsonCoil string
JSON file to take as input to generate Coil registers
-jsonDiscrete string
JSON file to take as input to generate Discrete registers
-jsonHolding string
JSON file to take as input to generate Holding registers
-jsonInput string
JSON file to take as input to generate input registers
-listenRTUTCPPort string
The address and port to listen on (default ":5502")
-registerStartOffset int
Use 0 or -1 (-1 is the default).
Do you want the register nr. to be specified as it is in the config file,
or to add 1 to the value ? -1 presents it as it is in the config file,
or setting the value to 0 will make the generator add 1 to the register
address specified in the config.
Example: if 0 is specified, a register with the address of 300 in the
config file will need to be read as 301 from modpoll. (default -1)